Skip Navigation LinksMidmark > Animal Health Products > Monitoring and Critical Care > TidalGuard™ HD Capnograph and Pulse Oximeter

TidalGuard™ HD Capnograph and Pulse Oximeter

Click images below for alternate views

    The new TidalGuard HD is more compact and portable than ever, with a crisp high-definition color screen and the choice between mainstream and sidestream CO2 combined with digital pulse oximetry. It’s designed to provide immediate clinical feedback of actual expired CO2. The TidalGuard HD helps provide critical information during anesthesia, such as depth of anesthesia, cardiac output and perfusion, and reliable respiration.

    Features:

    • Measures EtCO2, respiration rate, SpO2, pulse rate
    • Reduced to the size of a smart phone
    • New high-definition, bright color screen
    • Choose between mainstream or sidestream CO2
    • Diagnostic CO2/SpO2 waveforms
    • Audible/visual physiological and technical alarms
    • User adjustable alarm limits
    • Pre-set alarm limits for cats, dogs and horses
    • Three-hour graphical trend review
    • Up to 99 patient IDs, 72-hour tabular trend for each
    • Operates on four “AA” alkaline batteries or NiMH 2400 mAh rechargeable batteries (>4.5 hrs), or AC power
    • Power charger/cradle included
Click the links below to view the full product description.

General

  • Dimensions 4.8 x 2.9 x 0.9 in (125 x 73 x 23 mm)

  • Net weight 4.8 oz. (137 grams)

Electrical

  • External Power Supply: Includes AC adapter/charger

  • Power voltage: 100 – 240 V

  • Power frequency: 50/60 Hz

  • Battery (4xAA): NiMH 2400 mAh rechargeable or standard alkaline

  • Battery work time: SpO2 only - 10hr, CO2 + SpO2 – 4.5hr

Environmental

  • Operating Temperature: 32 – 122° F (0 – 50° C )

  • Operating Humidity: ≤95% relative (non-condensing)

Capnograph

  • Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts

  • Initialization Time: Capnogram within 15 seconds, full specifications within 2 minutes

  • Calibration: No regular calibration required

Capnostat®  Mainstream CO2 Sensor

  • Shock Resistance: Withstands repeated 6 ft drops on tiled floor

  • CO2 (Carbon Dioxide)
    Range: 0 – 150 mmHg
    Accuracy: ±2 mm Hg (0 – 40 mmHg), ±5% of reading (41 – 70 mmHg), ±8% of reading (71 – 100 mmHg), ±10% of reading (101 – 150 mmHg)
    Resolution: 0.1 mmHg (0-69mmHg), 0.25 mmHg (70-150mmHg)
    Response Time:  ≤60 ms

  • Respiratory Rate
    Accuracy: ±1 bpm Range
    0 – 150 bpm Resolution: 1 bpm

Pulse Oximeter

  • Principle of Operation: Red/Infrared absorption (Oxygen Saturation)

  • SpO2                                      
    Range: 0 – 100%
    Accuracy: ±2% SpO2 (for 70 – 100% SpO2) (1 SD), Unspecified for 0 – 69%
    Resolution: 1%

  • Pulse Rate
    Range: 30 – 250 bpm
    Accuracy: 1 bpm or ±2%, whichever is greater
    Resolution: 1 bpm

Accessory information for this product is currently unavailable online. For detailed information about Midmark accessories, please call our Customer Service Department at 1-800-MIDMARK.

Midmark Animal Health Store

Brochures

Technical Documentation

Please follow the link below to view our technical documentaton library.

Request Printed Literature

Please follow the link below to request printed literature for this and other Midmark products.
Color information for this product is currently unavailable online. For detailed information, please call our Customer Service Department at 1-800-MIDMARK.
Select the link below to download low-res and high-res images from our product image library.

Click here to view our image library.

Call Us Today

Click here to look up your Rep's phone number.

Evaluate this product with a Midmark Representative

First Name:*


Last Name:*


Company/Practice Name:*


Zip/Postal Code:*


Email Address:*


Phone:*