Features
Usage
Non-invasive, multi-parameter vital signs device
Data
Quick, easy entry and viewing of all vital signs data in one location
Windows based platform
Flexible, easy to upgrade software for the life of the product
Display
High resolution for optimal viewing and control. 7” VGA TFT LCD display with LED backlight and resistive touch screen
Internal Battery
Vital signs can be captured continuously and quickly without plugging in
100-reading memory
Easy for recall, printing or download of patient data
Multiple mounting options
Flexibility to meet different workflow needs; mobile cart, wall mount, countertop mount, IV pole mount
Connection
USB or serial connections standard
Digital scale
Supports the Fairbanks® TeleWeigh™ scale and Health o meter® digital scales (Note: Health o meter® digital scales require connection to a computer with IQmanager® software)
Warranty
Two (2) years for IQvitals®, one (1) year for blood pressure cuffs and SpO2 sensor, 90 days for other accessories included with kit
Safety Parameters
Type of Protection (Electrical)
Class II
Degree of Protection (Electrical)
Type BF
Degree of Protection (Water)
IPX1. Protection against dripping water.
Degree of Safety (Flammable Anesthetic Mixture)
Not suitable for use in the presence of a Flammable Anesthetic Mixture
Disinfecting Method
Per the instructions in the Cleaning section of the Operation Manual
Environmental Specifications
Operating Temperature
32 to 104 °F (0 to 40 °C) (For Patient Temperature Measurement: 16 to 33 °C)
Storage Temperature
-4 to 140 °F (-20 to 60 °C)
Operating Altitude
0 to 15,000 feet
Storage Altitude
0 to 40,000 feet
Operating Humidity
15 to 95% non-condensing
Storage Humidity
15 to 95% non-condensing
EMC Standard
Per IEC 60601-1-2 and FCC Part 15 (Emissions Class B)
Physical Characteristics
Weight
3.9 lbs (1.77 kg)
Dimensions
4 in. (W) x 10.5 in. (L) x 7 in (H), 10.16 cm x 17.78 cm x 26.67 cm
Power (unit)
Simultaneously operates and charges device when AC power is plugged in; low power indicator; automatic shutdown on low power
Power (battery)
Battery: rechargeable 10.8 V lithium ion battery; 4 hours to fully charge, 3 hours for 95% charge; operates 8 hours on full charge
Non-Invasive Blood Pressure
Method
Oscillometric
Cuff
Infant, Child, Small Adult, Adult, Adult Long, Large Adult, Large Adult Long, and Thigh
Derived Parameters
Systolic, Diastolic, and Mean Arterial Pressure (MAP)
Measurement Range
Systolic: 30 to 250 mmHg, Mean: 20 to 230 mmHg, Diastolic: 10 to 210 mmHg
Measurement Accuracy
Systolic: ±5mmHg, Mean: ±5mmHg, Diastolic: ±5mmHg
Pulse Rate Accuracy
±5% or ±2 BPM, whichever is greater
Pulse Rate Range
30 to 240 BPM
Initial Cuff Pressure
User-selectable
Temperature
Probe Type
Alaris Turbo Temp®
Measurement Scale
Fahrenheit(F), Celsius(C)
Measurement Type
Oral and Axillary
Measurement Range
Oral: 95 to 106°F
Axillary
95 to 106°F
Measurement Accuracy
±0.1°C (±0.2°F) (probe)
Measurement Time (seconds)
Predictive Oral: 8-10; Axillary: 13-20
Pulse Oximetry (SpO2) Specifications
Method Absorption
Spectrophotometric (dual wavelength)
SpO2 / PR Resolution
1 O2% / 1 BPM
Report Interval
1 second
Measurement Range
SpO2: 20 to 100%
PR
30 to 240 BPM
Measurement Accuracy
SpO2: 70 to 100%: ±2%, PR: ±5%