Midmark® 800 Digital Vital Signs Device
Capturing vital signs and weight manually can take up to 69 seconds longer per patient.1 Manual transcription of vital signs data produces an average error rate of 17%.2 Even manual blood pressure measurement can be inconsistent.3 Can you afford the wasted time and transcription errors that come with manual vital signs collection?
The Midmark® 800 Digital Vital Signs Device is a digital vital signs monitor designed for data accuracy, EMR connectivity and workflow efficiency. The 800 measures blood pressure, temperature, weight and SpO2—so you can standardize your vital signs process, improve staff efficiency and enhance patient care.
Accuracy
Averaging, spot, SPRINT protocol and custom BP mode options support your needs.
Linear and step deflation NIBP methods allow you to balance efficiency and patient comfort.
Optional SpO2 sensors from Nellcor® or Masimo® provide additional patient data.
Automated respiration rate is available on a select model.
Connectivity
Seamless EMR connectivity minimizes steps, reduces clicks and may help improve efficiency.
Midmark Connect bridges the gap between the 800 and your EMR—streamlining clinical workflows and supporting more accurate, timely patient data.
Efficiency
Automated vital signs capture may reduce error rates, wasted time and costly rework.
The large, high-contrast screen supports easy viewing and use in a variety of clinical environments.
Flexible for your workflow—configure vital signs capture to fit your needs and your space.
2 Fieler, V. K., Jaglowski, T., & Richards, K. (2013). Eliminating errors in vital signs documentation. Comput Inform Nurs, 31(9), 422-427; quiz 428-429. doi:10.1097/01.NCN.0000432125.61526.27 PMID:24080751
-
Resources
Brochures
Digital Diagnostics Connected Solutions Clinical Education White Paper: Validation of the Midmark Digital Vital Signs Ambulatory Vitals Signs Quick Reference Guide: Digital Vital Signs Minimum Computer Requirements Extended Warranty Midmark Delivery Services Repair + Service Solutions Product Part Numbers -
Technical Specifications
Weight
4.0 lb (1.8 kg) without Exergen® TemporalScanner®
Dimensions
4.7 lb (2.1 kg) with Exergen® TemporalScanner®
12" L x 4" W x 7" H (0.30 x 0.10 x 0.18 m) without the Exergen® TemporalScanner®
Power (AC adapter)
12" L x 4" W x 8" H (0.30 x 0.10 x 0.20 m) with the Exergen® TemporalScanner®
100 – 240 V / ~ 50 – 60 Hz / 700 mA Output: 15 V / 2 A
Battery
Rechargeable 10.8 V lithium ion battery
NIBP Method
Oscillometric
Derived parameters:
Systolic and diastolic pressures,
Initial cuff pressure
and Mean Arterial Pressure (MAP)
User-selectable
Temperature type
Exergen® TemporalScanner®
Measurement scale
Fahrenheit (F), Celsius (C)
Measurement type
Temporal
Method absorption
Spectrophotometric (dual wavelength)
SpO2 resolution
1 O2 %
PR resolution
1 BPM
Report interval
1 second
-
Support
-
EMR/EHR Partners